XHV2 (GV2)Motor tutelae circa ruptor

Description:

Applicationem

XHV2(GV2, GV3) series motrix tutelae ambitus ruptor utitur consilio modulari, forma artificiosa est, volumen parvum est, frangit protegit, intus ponit Hot Nullam, munus est validum, mobilitas est bona.

XHV2(GV2, GV3) series tutelae motoris circa ruptor praecipue adhibentur ad tutelam motorum in circuitu AC50/60Hz et breves circuitus tutelae motorum in circuitu AC50/60Hz, operativae intentionis usque ad 690V aestimatae, currentem operantem ab 0.1A ad 80A aestimavit, ut a. imprimis plena intentione incipiendi et abscindendi motores sub onere AC3, et pro tutela in circuitu 0.1 A-80A.


Product Detail

Product Tags

exemplar No.and significatio

product-description1

Product exemplum InA rated current De aptando range commutandi pro coponentibus A. De valore currenti disiuncta commutandi instant in agro InA Ordo No.
GV2-M(ME) 0.16 0.1-0.16 1.5 XHV2-32(GV2)-M01C
0.25 0.16-0.25 2.4 XHV2-32(GV2)-M02C
0.4 0.25-0.4 5 XHV2-32(GV2)-M03C
0.63 0.4-0.63 8 XHV2-32(GV2)-M04C
1 0.63-1 13 XHV2-32(GV2)-M05C
1.6 1-1.6 22.5 XHV2-32(GV2)-M06C
2.5 1.6-2.5 33,5 XHV2-32(GV2)-M07C
4 2.5-4 51 XHV2-32(GV2)-M08C
6.3 4-6.3 78 XHV2-32(GV2)-M10C
10 6-10 138 XHV2-32(GV2)-M14C
14 9-14 170 XHV2-32(GV2)-M16C
18 13-18 223 XHV2-32(GV2)-M20C
23 17-23 327 XHV2-32(GV2)-M21C
25 20-25 327 XHV2-32(GV2)-M22C
32 24-32 416 XHV2-32(GV2)-M32C
XHV2(GV2) ambitus motor tutelae ruptor

Table 1

XHV2(GV2)-M(ME)(P) ; XHV2(GV2)-RS XHV2(GV2)-PM

M01C

0.1-0.16 RS01C 0.1-0.16 PM01C 0.1-0.16

M02C

0.16-0.25 RS02C 0.16-0.25 PM02C 0.16-0.25

M03C

0.25-0.40 RS03C 0.25-0.40 PM03C 0.25-0.40

M04C

0.40-0.63 RS04C 0.40-0.63 PM04C 0.40-0.63

M05C

0.63-1 RS05C 0.63-1 PM05C 0.63-1

M06C

1-1.6 RS06C 1-1.6 PM06C 1-1.6

M07C

1.6-2.5 RS07C 1.6-2.5 PM07C 1.6-2.5

M08C

2.5-4 RS08C 2.5-4 PM08C 2.5-4

M10C

4-6.3 RS10C 4-6.3 PM10C 4-6.3

M14C

6-10 RS14C 6-10 PM14C 6-10

M16C

9-14 RS16C 9-14 PM16C 9-14

M18C

10-16 RS18C 10-16 PM18C 10-16

M20C

13-18 RS20C 13-18 PM20C 13-18

M21C

17-23 RS21C 17-23 PM21C 17-23

M22C

20-25 RS22C 20-25 PM22C 20-25

M32C

24-32 RS32C 24-32 PM32C 24-32
Potentia aestimata electromotoris trium phase moderatur ruptor (GV2 Motor praesidii circa ruptor)

Table 2

De aptando range of rated current id est (A) Vexillum potentiae trium-phasti electromotoris KW.AC-3, 50Hz/60Hz
230/240V 400V 415V 440V 500V 690V
0.1-0.16 - - -
0.16-0.25 - - -
0.25-0.40 - - -
0.4-0.63 0.37
0.63-1 0.37 0.37 0.55
1-1.6 0.37 0.55 0.75 1.1
1.6-2.5 0.37 0.75 0.75 1.1 1.1 1.5
2.5-4 0.75 1.5 1.5 1.5 2.2 3
4-6.3 1.1 2.2 2.2 3 3.7 4
6-10 2.2 4 4 4 5.5 7.5
9-14 3 5.5 5.5 7.5 7.5 9
13-18 4 7.5 9 9 9 11
17-23 5.5 11 11 11 11 15
20-25 5.5 11 11 11 15 18.5
24-32 7.5 15 15 15 18.5 23
De disiuncta currenti commutandi valorem ruptor in instanti propinquo
InA rated current De aptando range commutandi pro coponentibus A. De valore currenti disiuncta commutandi instant in agro InA
0.16 0.1-0.16 1.5
0.25 0.16-0.25 2.4
0.4 0.25-0.4 5
0.63 0,4-0.63 8
1 0.63-1 13
1.6 1-1.6 22.5
2.5 1.6-2.5 33.5
4 2.5-4 51
6.3 4-6.3 78
10 6-10 138
14 9-14 170
18 13-18 223
23 17-23 327
25 20-25 327
32 24-32 416

Accessories (referre ad mensam 4)

product-description2

Nomina accessiones Code genera contactus institutionem loci
Instantaneae contactus auxiliares AE1 11NO/1NC 1PCS) Fronte ruptor (1 PCS institui potest)
AE11 11NO+1NC
AE20 22NO
AN11 11NO+1NC ad sinistram ruptor (4PCS potest installed)
AN20 22NO
culpa signum contactus momentaneum contactus auxiliares AD1010 Constant-aperta tribulationis NO
AD1001 NC
AD0110 Constant-clausa tribulationis N。
AD0101 NC
Brevis circuitus contactus AM11 1NO、1NC

4.1 Contactus accessiones

Table 4

4.2 Electricdisjointing Table 5
Nomina accessiones Code Voltage institutionem loci
Indigentia disiunctio AU115 110-127V 50Hz Ius ruptoris (1 PCS institui potest)
AU225 220-240V 50Hz
AU385 380-415V 50Hz
Division disiunctio AS115 110-127V 50Hz
AS225 220-240V 50Hz
AS385 380-415V 50Hz
Utendum ad emissionem humilis voltage AX115 110-127V 50Hz
AX225 220-240V 50Hz
AX385 380-415V 50Hz
4.3 Casus tutelae ruptor Tabulae 6
Nomina accessiones Gradus tutelae causa Code Memo
Testa externam institutionem I P41 MC01
I P55 MC02
I P65 MC03

Externus determinatio dimensionis

5.1 Adumbratio et fixa dimensio ruptoris (GV2 Motor tutelae ambitus ruptor) (refer ad chart2, 3).
5.2 Praevaricator (GV2 Motricium tutelae ambitus ruptor) vexillum conductor inilam institutionem adoptat, conductor rail debet occurrere A2.1 TH35-7.5 typus institutionis regulae JB6525.
5.3 Externam institutionem GV2 Motoris tutelae circuitus ruptor (refer ad chart1.4).

product-description3 product-description4

4.12 Curva propria disiungendi (refer ad chart V) mediocris operis temporis secundum multiplicem commutandi venam.

product-description3

Pelagus technica parametri

1. Rated velit voltage Ui(V): 690;
2. Ratum opus intentionis (V): 230/240, 400/415, 440, 550, 690;
Ratum frequentia Hz: 50/60;
4. Gradus aestimatus vena testae Inm(A): 32;
5. Aestimata intentione disiunctivae ln(A)(J41 table 1);
6. De aptando range commutandi currentis (A) (mensa 1);
7. Secans capacitas aestimationis limitis ambitus breves lcu(kA)(tabula 7);
8. Secans capacitas operis aestimandi ambitum brevem lcs(kA)(tabula 7);
9. tolerabilis intentione pro rated Uimp incursu (V): 8000o

Proprietas actionis super- current tutelae.

Table 7

Ratum current ln (A) Adjusting ira commutandi current ICS Secatio capacitatis pro mensura mensurae brevis ambitus leu, sectio capacitas operis brevissimi circuli les . aestimandi Distantia arcuum (mm)
230/240V 400/415V 440V 500V 690V
lcu(ka) lcs (ka) lcu(ka) lcs (ka) lcu(ka) lcs (ka)

lcu(ka)

lcs (ka) lcu(ka) lcs (ka)
0.16 0.10-0.16 100 100 100 100 100 100 100 100 100 100 40
0.25 0.16-0.25 100 100 100 100 100 100 100 100 100 100 40
0.4 0.25-0.4 100 100 100 100 100 100 100 100 100 100 40
0.63 0.4-0.63 100 100 100 100 100 100 100 100 100 100 40
1 0.63-1 100 100 100 100 100 100 100 100 100 100 40
1.6 1-1.6 100 100 100 100 100 100 100 100 100 100 40
2.5 1.6-2.5 100 100 100 100 100 100 100 100 3 2.25 40
4 2.5-4 100 100 100 100 100 100 100 100 3 2.25 40
6.3 4-6.3 100 100 100 100 50 50 50 50 3 2.25 40
10 6-10 100 100 100 100 15 15 10 10 3 2.25 40
14 9-14 100 100 15 7.5 8 4 6 4.5 3 2.25 40
18 13-18 100 100 15 7.5 8 4 6 4.5 3 2.25 40
23 17-23 50 50 15 6 6 3 4 3 3 2.25 40
25 20-25 50 50 15 6 6 3 4 3 3 2.25 40
32 24-32 50 50 10 5 6 3 4 3 3 2.25 40

1 Actio propria ruptoris (GV2 Motor praesidii circa ruptor) cum omne tempus onus in statera est.

Table 8

Multiplex de currenti rated incipiens statum Tempus statutum Ob exitum Temperatus aeris ambientium
1.05 Frigus statum tN2h * Non disiunctio
1.2 Status calidus (surgit ad venam stipulatam post experimentum No 1) t<2h* Disiunctio +40°C±2°C
1.5 Unus-vicis commutandi current incipit cum bot statera t< 2min Disiunctio
7.2 Frigus statum 2 Disiunctio

2. Actio propria ruptoris (GV2 Motor praesidii circa ruptor) cum omne tempus onus in statera (phase-fractum).

Multiplex de currenti rated incipiens statum Tempus statutum Ob exitum Temperatus aeris ambientium
Aliqua duo tempora Tertius gradus
1.0 0.9 Frigus statum tw2h * Non disiunctio +40°C ± 2°C
1.15 0 Status calidus (surgit ad venam stipulatam post experimentum No 1) t<2h* Disiunctio

  • Priora:
  • Deinde:

  • Epistulam tuam hic scribe et mitte nobis